60
4.3 Diagnostic Test Procedure Using the Diagnostic Program
Insert the CD-R (HS7046EPH60SR supplied with the E6000H) into the CD-ROM drive of the host computer,
move the current directory to <Drive>:\Diag with a command prompt, and enter one of the following commands
according to the PC interface board used to initiate the diagnostic program:
1. PCI bus interface board (HS6000EIC01H or HS6000EIC02H)
> TM7046
–PCI (RET)
2. PC card interface (HS6000EIP01H)
> TM7046
–PCCD (RET)
3. LAN adapter (HS6000ELN01H)
> TM7046
–ELN (RET)
4. USB adapter (HS6000EIU01H or HS6000EIU02H)
> TM7046
–USB (RET)
The High-performance Embedded Workshop must be installed before the test program is executed.
Be sure to initiate the diagnostic program from <Drive>:\Diag. Do not initiate it from a directory other than
<Drive>:\Diag, such as > <Drive>:\Diag\TM7046
–PCI (RET). If the diagnostic program is initiated when the
current directory is not <Drive>:\Diag, the diagnostic program will not operate correctly.
When
–S is added to the command line such as > TM7046 –PCI –S (RET), steps 1 to 14 will be repeatedly
executed. To stop the execution, enter Q.
Notes: 1. <Drive> is a drive name for the CD-ROM drive.
2. Do not remove the CD-R from the CD-ROM drive during test program execution.