Renesas M16C/6V Informacje Techniczne

Przeglądaj online lub pobierz Informacje Techniczne dla Networking Renesas M16C/6V. Renesas M16C/6V Technical information Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
To our customers,
Old Company Name in Catalogs and Other Documents
On April 1
st
, 2010, NEC Electronics Corporation merged with Renesas Technology
Corporation, and Renesas Electronics Corporation took over all the business of both
companies. Therefore, although the old company name remains in this document, it is a valid
Renesas Electronics document. We appreciate your understanding.
Renesas Electronics website: http://www.renesas.com
April 1
st
, 2010
Renesas Electronics Corporation
Issued by: Renesas Electronics Corporation (http://www.renesas.com)
Send any inquiries to http://www.renesas.com/inquiry
.
Przeglądanie stron 0
1 2 3 4 5 6 ... 49 50

Podsumowanie treści

Strona 1 - To our customers

To our customers, Old Company Name in Catalogs and Other Documents On April 1st, 2010, NEC Electronics Corporation merged with Renesas Technology C

Strona 2

( 8 / 48 )Chapter 1. Precautions for SafetyIn both the user's manual and on the product itself, several icons are used to insure proper handlingo

Strona 3 - M306V0T-RPD-E

( 9 / 48 )1.2 Precautions for SafetyWARNINGWarning for Installation:• Do not set this product in water or areas of high humidity. Spilling water or so

Strona 4 - ( 2 / 48 )

( 10 / 48 )IMPORTANTNotes on PC4701 Emulators:• The PC4700H emulators whose serial number ends with a number cannot be used with M306V0T-RPD-E. Use on

Strona 5 - When using outside Japan

( 11 / 48 )IMPORTANTNotes on Connecting Target System:• When connecting the FLX100 flexible cable and the converter board, be careful not to forciblyp

Strona 6 - Contents

( 12 / 48 )IMPORTANTNotes on Differences between Actual MCU and Emulator:• Emulator operation differs from mask MCU operation, as listed below:(1) Res

Strona 7 - ( 5 / 48 )

( 13 / 48 )IMPORTANT(11) Actual MCU output and emulator outputTable 1.2 Actual MCU and emulator outputsOutputFloatingNo output(High output fixed)No ou

Strona 8 - Terminology

( 14 / 48 )Note on Changing Data in OSD RAM Area When Program is not Executed:•To change data when a program is not executed, write data when the map

Strona 9

( 15 / 48 )Note on Stack:• This product uses up to 8 bytes for stack.IMPORTANTNote on Reading MCU Internal Sources:• When this product is configured w

Strona 10 - CAUTION

( 16 / 48 )Figure 2.1 System configurationFollowing products (1) to (4) are attached to M306V0T-RPD-E.(1) Emulation pod (M306V0T-RPD-E)This emulation

Strona 11 - Cautions for Installation:

( 17 / 48 )Chapter 3. SpecificationsTable 3.1 lists the specifications of the M306V0T-RPD-E.Table 3.1 Specifications of the M306V0T-RPD-EItemUsable em

Strona 12

Notice 1. All information included in this document is current as of the date this document is issued. Such information, however, is subject to chang

Strona 13

( 18 / 48 )Chapter 4. Settings for Target Systems4.1 Positions of SwitchesFigure 4.1 shows positions of switches on the M306V0T-RPD-E.Figure 4.1 Posit

Strona 14

( 19 / 48 )4.2 SettingsTable 4.1 gives a list of switch settings.Table 4.1 Switch (SW) settingsIMPORTANTNote on Switch Settings:• Be sure to turn off

Strona 15

( 20 / 48 )4.3 Procedure for Setting Oscillation FrequencyIf you are using the emulation pod's internal oscillator, see (1) below. If you are usi

Strona 16

( 21 / 48 )Figure 4.3 Circuit of oscillator board OSC-2Figure 4.4 shows how to replace the oscillator board.(a) Remove the screw locking the oscillato

Strona 17

( 22 / 48 )Figure 4.5 External oscillator circuitFigure 4.6 Circuit for no oscillation in this pod(2) Using target system's oscillatora. To opera

Strona 18 - Chapter 2. Introduction

( 23 / 48 )4.4 Data Slicer I/O Signals and OSD Clock I/O Signal CircuitsFigure 4.7 shows the layout of the parts on the board and the circuit diagrams

Strona 19 - Chapter 3. Specifications

( 24 / 48 )(3) Figure 4.10 shows the part numbers and the constants of the parts of the signal VHOLD.Figure 4.10 VHOLD signal circuit(4) Figure 4.11 s

Strona 20 - 4.1 Positions of Switches

( 25 / 48 )4.5 Procedure for Setting Switches(1) You must remove the cover of the M306V0T-RPD-E in order to set the switches. To do so, removethe four

Strona 21

( 26 / 48 )Chapter 5. Method of Connection5.1 Connecting Emulator Main UnitUse the FLX120-RPD 120-pin flexible cable to connect the emulator main unit

Strona 22 - ( 20 / 48 )

( 27 / 48 )Connect FLX120-RPD with M306V0T-RPD-E. Figure 5.2 shows how to connect M306V0T-RPD-E and FLX120-RPD.Figure 5.2 Connecting M306V0T-RPD-E and

Strona 23 - ( 21 / 48 )

M306V0T-RPD-EUser’s ManualUser’s ManualRev.1.00 2003.10Emulation Pod for M16C/6V Group M306V0

Strona 24 - ( 22 / 48 )

( 28 / 48 )5.2 Connecting Target SystemFigure 5.3 shows connections between emulator probes and target systems. For more details, referto "Renesa

Strona 25 - ( 23 / 48 )

( 29 / 48 )Chapter 6. Constraints(1) BRK instructionThe BRK instruction cannot be used.(2) Software and hardware breaksa. Do not set simultaneous soft

Strona 26 - ( 24 / 48 )

( 30 / 48 )Chapter 7. Operation Timing (Memory Expansion and Microprocessor Modes)7.1 Separate Bus (no wait)Table 7.1 and Figure 7.1 show bus timing w

Strona 27 - ( 25 / 48 )

( 31 / 48 )Figure 7.1 Memory expansion mode and microprocessor mode (separate bus, no wait)Read timingWrite timingVcc = 5 VMemory expansion mode or mi

Strona 28 - ( 26 / 48 )

( 32 / 48 )7.2 Separate Bus (with wait), When Accessing to External Memory AreaTable 7.2 and Figure 7.2 show bus timing when using the memory expansio

Strona 29 - Note on Connecting the Cable:

( 33 / 48 )Figure 7.2 Memory expansion mode and microprocessor mode (separate bus, with wait)Measurement Condition• VCC = 5 V• Input timing voltage: V

Strona 30 - 5.2 Connecting Target System

( 34 / 48 )7.3 Multiplex Bus (with wait), When Accessing to External Memory AreaTable 7.3 and Figure 7.3 show bus timing when using the memory expansi

Strona 31 - Chapter 6. Constraints

( 35 / 48 )Note 1. Compute bus timing according to BCLK frequency. Use the below formula.th(RD-AD) = 109[ns] td(DB-WR) = 109x3 - 40 [ns] f(

Strona 32 - 7.1 Separate Bus (no wait)

( 36 / 48 )Figure 7.3 Memory expansion mode and microprocessor mode (multiplex bus, with wait)Memory expansion mode or microprocessor mode(with wait,

Strona 33 - Vcc = 5 V

( 37 / 48 )7.4 Timing RequirementsTable 7.4 and Figure 7.4 show timing requirements when using the memory expansion mode andmicroprocessor mode.Table

Strona 34

( 2 / 48 )* IBM and PC/AT are registered trademarks of International Business Machines Corporation.Keep safety first in your circuit designs!• Renesas

Strona 35

( 38 / 48 )Figure 7.4 Timing requirements (Vcc = 5 V)Measurement Condition• VCC = 5 V• Input timing voltage: VIL = 1.0 V, VIH = 4.0 V• Output timing v

Strona 36

( 39 / 48 )Chapter 8. Electrical CharacteristicsTables 8.1 and 8.2 show IC electrical characteristics of user's interface.Table 8.1 Electrical ch

Strona 37 - ( 35 / 48 )

( 40 / 48 )Chapter 9. Maintenance and Guarantee9.1 MaintenanceIf dust or dirt collects on any equipment of your emulation system, wipe it off with a d

Strona 38

( 41 / 48 )9.4 How to Request for RepairIf your product is found faulty, follow the procedure below to send your product for repair.Customer Fill in t

Strona 39 - 7.4 Timing Requirements

( 42 / 48 )Chapter 10. Troubleshooting10.1 When M306V0T-RPD-E Does Not Work Properly(1) Emulator main unit cannot be powered up.Check to see if the AC

Strona 40

( 43 / 48 )Appendix A. External DimensionsA.1 External Dimensions of the M306V0T-RPD-EFigure A.1 External dimensions of the M306V0T-RPD-EUnit: mm

Strona 41 - 3 - P57, 5 V)

( 44 / 48 )A.2 External Dimensions of the FLX-100LCCFigure A.2 External dimensions of the FLX-100LCCUnit: mm

Strona 42 - 9.3 Repair Provisions

( 45 / 48 )Appendix B. Connection DiagramsFigures B.1 and B.2 show the connection diagrams of the M306V0T-RPD-E. These connectiondiagrams mainly show

Strona 43 - 9.4 How to Request for Repair

( 46 / 48 )Figure B.2 Connection diagram of the M306V0T-RPD-E (2/2)

Strona 44 - Chapter 10. Troubleshooting

M306V0T-RPD-E User's ManualRev.1.00October 16, 2003REJ10J0380-0100ZCOPYRIGHT ©2003 RENESAS TECHNOLOGY CORPORATIONAND RENESAS SOLUTIONS CORPORATIO

Strona 45 - Unit: mm

( 3 / 48 )PrefaceThe M306V0T-RPD-E is an emulation pod for the M16C/6V group of Renesas 16-bit MCUs. TheM306V0T-RPD-E is used by being connected to th

Strona 46

1753, Shimonumabe, Nakahara-ku, Kawasaki-shi, Kanagawa 211-8668 JapanM306V0T-RPD-EREJ10J0380-0100ZUser’s Manual

Strona 47 - ( 45 / 48 )

( 4 / 48 )ContentsTerminology ...

Strona 48 - ( 46 / 48 )

( 5 / 48 )Chapter 5. Method of Connection ...265.1 Connecting Emu

Strona 49 - REJ10J0380-0100Z

( 6 / 48 )TerminologySome specific words used in this User's Manual are defined as follows:PC4701This means the generic name of the PC4701HS, PC4

Strona 50 - User’s Manual

( 7 / 48 )Things to Check When UnpackingThe M306V0T-RPD-E consists of the following parts and manuals. When unpacking, check to seeif your M306V0T-RPD

Komentarze do niniejszej Instrukcji

Brak uwag