Renesas M38000TL2-FPD Informacje Techniczne

Przeglądaj online lub pobierz Informacje Techniczne dla Networking Renesas M38000TL2-FPD. Renesas M38000TL2-FPD Technical information Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
To our customers,
Old Company Name in Catalogs and Other Documents
On April 1
st
, 2010, NEC Electronics Corporation merged with Renesas Technology
Corporation, and Renesas Electronics Corporation took over all the business of both
companies. Therefore, although the old company name remains in this document, it is a valid
Renesas Electronics document. We appreciate your understanding.
Renesas Electronics website: http://www.renesas.com
April 1
st
, 2010
Renesas Electronics Corporation
Issued by: Renesas Electronics Corporation (http://www.renesas.com)
Send any inquiries to http://www.renesas.com/inquiry
.
Przeglądanie stron 0
1 2 3 4 5 6 ... 55 56

Podsumowanie treści

Strona 1 - To our customers

To our customers, Old Company Name in Catalogs and Other Documents On April 1st, 2010, NEC Electronics Corporation merged with Renesas Technology C

Strona 2

( 8 / 54 )Chapter 1. Precautions for SafetyIn both the user's manual and on the product itself, several icons are used to insure proper handlingo

Strona 3 - M38000TL2-FPD

( 9 / 54 )WARNINGWarning for Installation:• Do not set this product in water or areas of high humidity. Spilling water or some other liquid intothe ma

Strona 4 - ( 2 / 54 )

( 10 / 54 )(1) Set the target system on a platform to relax bendsand relieve stress in the board.(2) The boundary between the firm and flexible partso

Strona 5 - When using outside Japan

( 11 / 54 )IMPORTANTNote on Malfunctions in the PC4701 System:• If the emulator malfunctions because of interference such as external noise, do the fo

Strona 6 - Terminology

( 12 / 54 )IMPORTANTNote on Differences between Actual MCU and Emulator:•Operations of the emulator differ from those of mask MCUs as listed below.(1)

Strona 7 - Contents

( 13 / 54 )Note on When the Emulator Debugger Ends:• To restart the emulator debugger after it ends, always shut power to the emulator module off once

Strona 8 - ( 6 / 54 )

( 14 / 54 )MEMO

Strona 9 - ( 7 / 54 )

( 15 / 54 )Chapter 2. PreparationThis chapter describes the package components, the system configuration and the preparation for using this product fo

Strona 10 - CAUTION

( 16 / 54 )Please keep the M38000TL2-FPD's packing box and cushion material in your place for reuse at a latertime when sending your product for

Strona 11 - Warnings for Use Environment:

( 17 / 54 )2.3 Name of Each PartFigure 2.1 System configurationFigure 2.2 M38000TL2-FPD(1) Emulation pod (M38000TL2-FPD)This emulation pod contains an

Strona 12

Notice 1. All information included in this document is current as of the date this document is issued. Such information, however, is subject to chang

Strona 13

( 18 / 54 )2.4 When Using the Emulator for the First TimeIf you have purchased this emulation pod newly, it is necessary to download the firmware. The

Strona 14

( 19 / 54 )Chapter 3. Setting UpThis chapter describes switch settings required for using this product and how to connect this product to the PC4701 a

Strona 15

( 20 / 54 )Chapter 3. Setting UpWith this product, it is necessary to set switches of the emulation pod and connect the RESET, GNDand Vcc cables accor

Strona 16 - ( 14 / 54 )

( 21 / 54 )3.2 Selecting Clock SupplyWith this product, the oscillator circuit on the target system is always used to supply a clock to theMCU. To sel

Strona 17 - Chapter 2. Preparation

( 22 / 54 )3.3 Connecting the PC4701To connect the emulation pod to the PC4701, use the 120-pin flexible cable included with this productpackage. Conn

Strona 18

( 23 / 54 )3.4 Connecting the Emulator MCUThere are following three methods to connect the emulator MCU and M38000TL2-FPD, so you canchoose the approp

Strona 19 - 2.3 Name of Each Part

( 24 / 54 )(1) When Emulator MCU is an RSS or RLSS ChipIf the emulator MCU is an RSS or RLSS chip, use the 28DP-WS board as the probe directionconvert

Strona 20 - (page 22)

( 25 / 54 )(2) When Emulator MCU is an RFS or RLFS Chip with Screw-lockIf the emulator MCU is an RFS or RLFS chip with a screw-lock, use the 32LCC-S b

Strona 21 - Chapter 3. Setting Up

( 26 / 54 )3.5 Connecting the Target SystemUse the suitable converter for your package to connect the emulator MCU and the target system.For details o

Strona 22

( 27 / 54 )3.6 M38000TL2-PSW (RESET, GND and Vcc Cables with Overcurrent Protective Circuits)The M38000TL2-PSW is an upgraded version of the RESET, GN

Strona 23

M38000TL2-FPDUser’s ManualUser’s ManualRev.2.00 2003.11Emulation Pod for 740 Family MCUs

Strona 24 - Note on Securing the Screws:

( 28 / 54 )(2) Connecting the M38000TL2-PSW to the M38000TL2-FPDConnect the M38000TL2-PSW to the M38000TL2-FPD. Connect the connector matching the col

Strona 25 - ( 23 / 54 )

( 29 / 54 )(3) Connecting the M38000TL2-PSW to the Target SystemConnect the clips for RESET, GND and Vcc on the tip of the M38000TL2-FPD's three-

Strona 26 - ( 24 / 54 )

( 30 / 54 )Figure 3.13 Connection diagram of reset circuit(4) LED DisplayThe M38000TL2-PSW turns off the LED to alert you when Vcc and GND are mistake

Strona 27 - ( 25 / 54 )

( 31 / 54 )Chapter 4. UsageThis chapter describes from turning on the power of this product to starting up the emulator debugger.4.1 Turning On the Po

Strona 28 - ( 26 / 54 )

( 32 / 54 )Chapter 4. Usage4.1 Turning On the Power Supply(1) Checking the Connection of the SystemBefore turning the power ON, check the connection o

Strona 29 - ( 27 / 54 )

( 33 / 54 )(3) LED Display When the PC4701 Starts Up NormallyAfter the emulator starts up, check the status of the LEDs on the front panel to see whet

Strona 30 - ( 28 / 54 )

( 34 / 54 )4.2 Downloading Firmware(1) When It is Necessary to Download FirmwareIt is necessary to download firmware when:(1) you use this product for

Strona 31

( 35 / 54 )4.3 Self-check(1) Self-check ProcedureTo run the emulator self-check, do so as explained here below. While the self-check is in progress,LE

Strona 32 - (4) LED Display

( 36 / 54 )Figure 4.3 LED display when self-checking

Strona 33 - Chapter 4. Usage

( 37 / 54 )Chapter 5. SpecificationsThis chapter describes specifications of this product.5.1 Specifications ...

Strona 34

( 2 / 54 )Keep safety first in your circuit designs!• Renesas Technology Corporation and Renesas Solutions Corporation put the maximum effort into mak

Strona 35 - ( 33 / 54 )

( 38 / 54 )Chapter 5. Specifications5.1 SpecificationsTable 5.1 lists the specifications of the M38000TL2-FPD.Table 5.1 Specifications of the M38000TL

Strona 36 - Note on Downloading Firmware:

( 39 / 54 )Figure 5.1 External dimensions of the emulation pod5.2 External Dimensions(1) External Dimensions of the Emulation PodUnit: mm

Strona 37 - Note on the Self-check:

( 40 / 54 )Figure 5.2 External dimensions of the converter board 28DP-WS(3) External Dimensions of the Converter Board (32LCC-S)Figure 5.3 shows the e

Strona 38 - ( 36 / 54 )

( 41 / 54 )Chapter 6. TroubleshootingThis chapter describes how to troubleshoot when this product does not work properly.6.1 Flowchart to Remedy the T

Strona 39 - Chapter 5. Specifications

( 42 / 54 )Chapter 6. Troubleshooting6.1 Flowchart to Remedy the TroublesFigure 6.1 shows the flowchart to remedy the troubles from when power to the

Strona 40

( 43 / 54 )(2) When the LED Display of PC4701 is AbnormalTable 6.2 LED's abnormal display and its checkpoints(3) When the Init Dialog is Not Disp

Strona 41 - 5.2 External Dimensions

( 44 / 54 )(4) When the Program Window is Not Displayed NormallyTable 6.3 Checkpoints of errors when starting up the emulator debuggerErrorThe emulati

Strona 42

( 45 / 54 )6.2 When an Error Message "Cannot be reset" is DisplayedWhen an error message "Target MCU cannot be reset. Reset the target

Strona 43 - Chapter 6. Troubleshooting

( 46 / 54 )Check whether power (within the MCU's specified range and between +0.9 and 5.5 V) andGND are supplied to the target system.Check wheth

Strona 44

( 47 / 54 )6.5 FAQsHere following are frequently asked questions for using this product other than the troubles shownin the antecedent. For the latest

Strona 45

( 3 / 54 )PrefaceThe M38000TL2-FPD is an emulation pod for the 740 Family of Renesas 8-bit MCUs. It is used witha PC4701 emulator.This user's man

Strona 46

( 48 / 54 )MEMO

Strona 47 - ( 45 / 54 )

( 49 / 54 )Chapter 7. Maintenance and GuaranteeThis chapter describes how to maintenance, repair provisions and how to request for repair.7.1 Maintena

Strona 48

( 50 / 54 )Chapter 7. Maintenance and Guarantee7.1 MaintenanceIf dust or dirt collects on any equipment of your emulation system, wipe it off with a d

Strona 49 - 6.5 FAQs

( 51 / 54 )7.4 How to Request for RepairIf your product is found faulty, follow the procedure below to send your product for repair.Customer Fill in t

Strona 51 - ( 49 / 54 )

M38000TL2-FPD User's ManualRev.2.00November 1, 2003REJ10J0072-0200ZCOPYRIGHT ©2003 RENESAS TECHNOLOGY CORPORATIONAND RENESAS SOLUTIONS CORPORATIO

Strona 52 - 7.3 Repair Provisions

1753, Shimonumabe, Nakahara-ku, Kawasaki-shi, Kanagawa 211-8668 JapanM38000TL2-FPDREJ10J0072-0200ZUser’s Manual

Strona 53 - 7.4 How to Request for Repair

( 4 / 54 )TerminologySome specific words used in this user's manual are defined as follows:Emulator systemThis means an emulator system built aro

Strona 54 - ( 52 / 54 )

( 5 / 54 )ContentsChapter 1. Precautions for Safety ...71.1 Sa

Strona 55 - REJ10J0072-0200Z

( 6 / 54 )Chapter 5. Specifications .......375.1 Specif

Strona 56 - User’s Manual

( 7 / 54 )Chapter 1. Precautions for SafetyThis chapter describes precautions for using this product safely and properly. For precautions for the emul

Komentarze do niniejszej Instrukcji

Brak uwag