High: The status of the IRQ signal is high.
Low: The status of the IRQ signal is low.
[Timestamp]: Sets the time stamp condition.
[Don't care]: Detects no time stamp value when this box is checked.
[Setting]: Detects the specified time stamp value.
[Point]: Specifies a single time stamp.
[Range]: Specifies a time stamp range.
[From]: Enter a single time stamp value or the minimum value of the time stamp
range.
The format is as follows:
hour: h, minute: min, second: s, millisecond: ms, microsecond: us,
nanosecond: ns
[To]: Enter the maximum value of the time stamp range.
The format is the same as that in [From].
Set filtering conditions and then press the [OK] button. This starts filtering according to the conditions. Clicking
the [Cancel] button closes the [Trace Filter] dialog box, which holds the settings at the time when the dialog box
was opened.
In filtering, only the trace information that satisfies one or more filtering conditions set in the above pages will
be displayed in the [Trace] window.
Filtering conditions can be changed several times to analyze data because the content of the trace buffer is not
changed by filtering.