71
(2) Start Point To End Point Measurement
Figure 3.39 Start Point To End Point Measurement Settings
[Range Name]: The name of the range to be measured
[Point]: The range for the Start Point To End Point Measurement
[Start Address]: Address to start measurement
[End Address]: Address to end measurement
[Time Out Action]: The action to take when a timeout or count-out occurs.
Disable: Disables setting of a timeout or count-out value.
Enable: Stops the user program execution when a timeout or count-out occurs.
Trace Stop: Stops trace acquisition when a timeout or count-out occurs.
This is only available for channel 1.
[Time Out]: The timeout value to finish measurement. When the minimum time for measurement
is 160 ns, 40 ns, or 20 ns, enter the value as follows.
Example: 1h 2min 3s 123ms 456us 789ns
If the CPU operating mode is target, enter a hexadecimal number in 10 digits.
Example: 123456789A
A break occurs every time a value measured in the specified range exceeds the
timeout value (not the total time). This is only available for channel 1.