4.2.7 38BMulti Function Timer Pulse Unit
Description (2/5) [data3]
Configure the counter operation.
[data3]
Configure the IO control registers.
b0:b7 Timer I/O Control Register (TIORH_0, TIOR_1, TIOR_2, TIORH_3, TIORH_4)
[data4]
Configure the IO control registers.
b0:b7 Timer I/O Control Register (TIORL_0, TIORL_3, TIORL_4)
[data5]
The register TCNT value.
[data6]
The register TGRA value.
[data7]
The register TGRB value.
[data8]
The register TGRC value
[data9]
The register TGRD value
[data10]
The register TGRE value.
[data11]
The register TGRF value.
[data12]
Configure event interrupt priority value.
[data13]
Configure Over/Underflow interrupt priority value.
Return value
True if all parameters are valid and exclusive; otherwise false.
Category
Multi-function timer pulse unit
Reference
R_MTU_Destroy
Remarks • If an external clock input pin (TCLKx) or I/O pin (TIOCxn) is made active, this function will configure
that pin for input or output and disable other functions on that pin.
• The external clock inputs TCLKA, TCLKB, TCLKC and TCLKD are allocated to pins TCLKA-A,
TCLKB-A, TCLKC-A and TCLKD-A by default.
To select the –B group of pins, use API function R_PFC_Modify(5, 0x08, PDL_PFC_OR) to write 1 to bit
TCLKS in register PFCR5 before calling this function.
Note that these clock inputs are used by channels 0 to 5.
• If the channel is configured for phase counting mode, the counter clock source setting is ignored
• If buffer operation is selected for registers TGRA and TGRC, input capture / output compare is not valid
for register TGRC.
• If buffer operation is selected for registers TGRB and TGRD, input capture / output compare is not valid
for register TGRD.
• If synchronous mode is required, at least two channels must be enabled for synchronous operation.