R32C/100 E30A Emulator Debugger Release Notes
REJ10J2119-0100 Rev.1.00 Page 2 of 9
Dec 01, 2010
1. Notes
1.1 Installation
When this emulator debugger is installed, the MCU files (*.mcu) underneath the McuFiles folder *1 are moved into the
Old_McuFiles folder *2.
*
1: HEW installed folder\Tools\Renesas\DebugComp\platform\PDTarget\PD100E30A\McuFiles
*
2: HEW installed folder\Tools\Renesas\DebugComp\platform\PDTarget\PD100E30A\McuFiles\Old_McuFiles
1.2 Line Assembly
Regardless of the Radix setting, the default for line assembly input is decimal. Specify H as the radix for a hexadecimal
input.
1.3 Line Assembly
Regardless of the Radix setting, the default for line assembly input is decimal. Specify H as the radix for a hexadecimal
input.
1.4 Event Setting
1. TAB order in Set Event Status dialog box
Even when you press [TAB] key, the next input control may not be focused on the Set Event
Status dialog boxes opened from Event Setting Window.
2. In-place-edit mode on event list
On event list in Event Setting Window, High-performance Embedded Workshop will not escape
from in-place-edit mode even when you press the [ESC] key.
3. Event Settings Unaccepted Area
Do not set events in the area given below.
01000000h - FEFFFFFFh
1.5 Trace
1. Specifying function in SRC mode
In the SRC mode, when you specify a function to display it, if the current displayed source file
includes the function, the top of the source file will be displayed.
2. Saving of tracing result in text
When you save a tracing result in text with only “BUS” and “DATA” buttons ON, the vertical
position of some headers will shifts from the corresponding data. Check “Tab Separated Format”
and open it with spreadsheet applications to display them correctly.
3. Time concerned data
Time display at each cycle is not supported.
4. Loading the trace image file
Trace window can not load the trace image file saved by PDxx debuggers. And also, trace window
can not load the trace image file saved by the different target from the current target.
1.6 RAM Monitor
1. Proportional Fonts
When a proportional font is selected, a part of the characters in the view may be hidden. Fixed
fonts are recommended.
1.7 Memory
1. 8 bytes data operations
To set, fill, and copy 8 bytes data are not supported.