Renesas M3A-HS85 Informacje Techniczne Strona 10

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 23
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 9
SH7285 Group
Example of Initialization
REJ06B0860-0100/Rev.1.00 June 2009 Page 8 of 21
2.4 Setting in the Sample Program
Table 2 lists the setting in the sample program. Table 3 and
Table 4 list register settings for each module.
Table 2 Module Setting in the Sample Program
Module Setting
Clock pulse generator (CPG)
Clock frequency (input clock is 12.5 MHz)
Internal clock: 100 MHz
Bus clock: 50 MHz
Peripheral clock: 50 MHz
MTU2S clock: 50 MHz
AD clock: 50 MHz
Modules cleared the module standby function
MTU2S, MTU2, POE2, IIC3, ADC0, ADC1, CMT, SCIF3, SCI0,
SCI1, SCI2, SCI4, SSU, USB
Table 3 CPG Register Settings (1/2)
Register Name Address Setting Description
Frequency control register
(FRQCR)
H'FFFE 0010 H'0101
STC[2:0] = "B'001":
Bus clock (Bφ) division ratio: 2
IFC[2:0] = "B'000":
Internal clock (Iφ) division ratio: 1
PFC[2:0] = "B'001":
Peripheral clock (Pφ) division ratio = 2
MTU2S clock frequency
control register (MCLKCR)
H'FFFE 0410 H'41
MSDIVS[1:0] = "B'01":
MTU2S clock (Mφ) division ratio =2
AD clock frequency control
register (ACLKCR)
H'FFFE 0414 H'41
ASDIVS[1:0] = "B'01":
AD clock (Aφ) division ratio = 2