M32R Debugger and Trace 2 3 T r O n c h i p
©1989-2014 Lauterbach GmbH
TrOnchip.RESet Resets all TO settings
Resets the trigger system to the default state.
TrOnchip.VarCONVert Convert variable breakpoints
When enabled (default) the on-chip breakpoints are automatically converted from a range to a single
address if required. If the switch is off, the system will only accept breakpoints which exactly fit to the on-chip
breakpoint hardware.
The ICE-breaker does not provide resources to set an on-chip breakpoint to an address range. Only bit
masks can be used to mark a memory range with a breakpoint.
If TrOnchip.VarCONVert is set to ON and a breakpoint is set to a scalar variable then it is converted into a
single address breakpoint.
If TrOnchip.VarCONVert is set to OFF variable breakpoints will be set to an address range covering the
whole variable.
TrOnchip.view Opens configuration panel
Control panel to configure the on-chip breakpoint and trace registers. The details are described in section
TrOnchip.
Format: TrOnchip.RESet
Format: TrOnchip.VarCONVert [OFF | ON]
Format: TrOnchip.view