Renesas Technology, Tools FAQs
Last Updated: April 12, 2004
Document Number: 04032202_e
Q.
When the D flag is set to 1 (the decimal operation mode enabled), the execution of a program with breakpoints cannot be halted at
these breakpoints, and also single-step execution cannot properly be performed.
A.
Please confirm the firmware version number. If the number is lower than Ver.1.02.00, you need to update the firmware.
To confirm the firmware version number:
(1)Launch the M3T-PD38M.
(2)Open the Help menu and select the About command.
(3)In the Version dialog box that appears, check the version of the M38000A1.C0 firmware file.
To update the firmware:
Please replace the M38000A1.C0 firmware file in your product with the problem-fixed one (Ver.1.02.00) as follows:
(1)Download the compressed firmware file "firm.exe" (154KB) from the following RENESAS TOOL NEWS.
Issue Date: March 16, 2004
Title: Notes on Using Compact Emulator M38000T2-CPE
URL: http://tool-support.renesas.com/eng/toolnews/n040316/tn8.htm
(2)Decompress the firm.exe file to obtain the M38000A1.C0 Ver.1.02.00 and Readme_e.txt files.
(3)Follow the steps shown in Readme_e.txt to update the firmware file.
Top of Page | Back to Previous Page