Renesas Technology, Tools FAQs
Last Updated: March 20, 2001
Document Number: 01051145_e
Q.
When I build with TM, a double definition error occurs in an identical file. How can I prevent this error from occurring?
[Example of error]
ERROR NO.10: "NAME00" is multiple defined in .\TES.R74. others in TES.R74
A.
In terms of the above example, this error occurs due to the following situation:
When "TES.R74" is specified in the SRA74 (or RASM77) directive command ".OBJ", and the "TES.R74" source file is added to
the TM project, TM automatically creates the process up through the link step. This results in duplicate links for TES.R74 and an
error occurs at the label definition location.
When you are using TM, make sure you delete ".OBJ" from the source program.