7
Section 2 Specifications of the Software when Using the
SH7616
2.1 Differences between the SH7616 and the Emulator
1. When the emulator system is initiated, it initializes the general registers and part of the control
registers as shown in table 2.1. The initial values of the actual SH7616 registers are undefined.
When the emulator is initiated from the workspace, a value to be entered is saved in a session.
Table 2.1 Register Initial Values at Emulator Link Up
Register Emulator at Link Up
R0 to R14 H'00000000
R15 (SP) Value of the SP in the vector address table
PC Value of the PC in the vector address table
SR H'000000F0
GBR H'00000000
VBR H'00000000
MACH H'00000000
MACL H'00000000
PR H'00000000
RS H'00000000
RE H'00000000
MOD H'00000000
A0G, A1G H'00000000
A0, A1 H'00000000
X0, X1 H'00000000
Y0, Y1 H'00000000
M0, M1 H'00000000
DSR H'00000000
2. The emulator uses the H-UDI; do not access the H-UDI.