Renesas SuperH SH7600 Series Instrukcja Użytkownika Strona 12

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 23
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 11
6
When the circuit is connected as shown in figure 1.3, the switches of the emulator are set as SW2
= 0 and SW3 = 1. For details, refer to section 3.8, Setting the DIP Switches, in the Debugger Part
of the SuperH
TM
Family E10A-USB Emulator User’s Manual.
1
TCK
TMS
RESET
TDI
TDO
TRST
N.C.
GND
GND
GND
GND
(GND)
2
3
4
5
6
7
ASEMODE
8
9
11
10
12
13
14
TCK
RES
TMS
TDO
TDI
TRST
VccQ
N.C.
VccQ
VccQ
N.C.
H-UDI port connector
(14-pin type)
Reset signal
Pulled-up at 4.7 k or more (all)
User system
VccQ = 3.3 V (I/O power supply)
VccQ VccQ
SH7616
Figure 1.3 Circuit for Connection between the H-UDI Port Connector and MPU when the
Emulator is in Use (14-Pin Type UVCC Not Connected*)
Note: When UVCC is not connected and the user system is turned off, note that the leakage
current flows from the emulator to the user system.
Przeglądanie stron 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 22 23

Komentarze do niniejszej Instrukcji

Brak uwag