( 21 / 44 )
(1) Using the Oscillator Circuit on the Target System
When turning on the power supply, the internal clock of the emulation pod is selected to supply the
clock to the MCU. To use the external clock on the target system, change the clock by the Init dialog
or the CLK command of the emulator debugger. (For details, refer to the user's manual of the emulator
debugger.)
IMPORTANT
Notes on External Clock:
• To operate the emulation pod with an external clock, construct the oscillator circuit
as shown in Figure 3.1 in the target system and input the oscillator output at 50% duty
(within the operating range of the emulator MCU) into the XIN pin. And the XOUT pin
should be open (same for XCIN).
• Make note of the fact that in the oscillator circuit shown in Figure 3.2 where a
resonator is connected between the XIN and XOUT pins, oscillation does not occur
because a flexible cable, buffer IC and other devices are used between the emulator
MCU and the target system (same for XCIN).
• To use the external clock supply for XCIN, set the JP3 shown in "3.2 Switch Settings"
to "P52" side.
Figure 3.1 External oscillator circuit
Figure 3.2 Circuit in which oscillation does not occur