MAEC TECHNICAL NEWS
No.M16C-75-0110
(1/ 2)
A
GRADE
Corrections and Supplementary Explanation for M16C/20 Series, M16C/60
Series, M16C/80 Series Data Sheet and User's Manual
This is to inform you of the errors that have been found in the data sheets and user's manuals of the
M16C/20, M16C/60 and M16C/80 Series. The error statements found in each data sheet and user's
manual of the said series may not be exactly the same as the ones shown below. So please rectify
the equivalent errors as shown below.
Data Sheet
Location: Timer B, pulse period/pulse width measurement mode
Error: The timer Bi overflow flag changes to "0" when the count start flag is "1" and a value is
written to the timer Bi mode register.
Correction: Assume that the count start flag condition is "1" and then the Timer Bi overflow flag
becomes "1". If the Timer Bi mode register has a write-access after next count cycle
of the timer from the above condition, the Timer Bi overflow flag becomes "0".
Location: Timer X (exist in M30201 Group), pulse period/pulse width measurement mode
Error: The timer Xi overflow flag changes to "0" when the count start flag is "1" and a value is
written to the timer Xi mode register.
Correction: Assume that the count start flag condition is "1" and then the Timer Xi overflow flag
becomes "1". If the Timer Xi mode register has a write-access after next count cycle
of the timer from the above condition, the Timer Xi overflow flag becomes "0".
User's Manual
Location: Hardware, timer B, pulse period/pulse width measurement mode
Error: The timer Bi overflow flag changes to "0" when the count start flag is "1" and a value is
written to the timer Bi mode register.
Correction: Assume that the count start flag condition is "1" and then the Timer Bi overflow flag
becomes "1". If the Timer Bi mode register has a write-access after next count cycle
of the timer from the above condition, the Timer Bi overflow flag becomes "0".
Classification
Corrections and supplementary
explanation of document
Notes
Knowhow
Others
Products Effected
M16C/20 Series (Except for M16C/24 Group)
M16C/60 Series
M16C/80 Series