5. Flash Development Toolkit Processing
The Flash Development Toolkit can be connected in either of the following two modes: the boot mode or the user
program mode. In both modes, the continuation of the execution from a previous session can be specified. The
connection modes of the Flash Development Toolkit are listed in
Table 5-1. Normally, a new connection processing is
used. The hexadecimal code is a command code of the Flash Development Toolkit. For details, refer to the description
on flash memory (0.18-μm F-ZTAT version) in the Hardware Manual.
Table 5-1 Connection Modes of the Flash Development Toolkit
Mode New Connection Processing Continuation of the Execution from a Previous
Session
Boot mode Baud rate adjustment
H'27 (Programming unit inquiry)
H'10 (Device selection)
H'11 (Clock mode selection)
H'3F (New baud rate setting)
H'27 (Programming unit inquiry)
H'4F (Status request)
H'4D (User area blank check)
User boot mode
User program mode
H'27 (Programming unit inquiry)
H'10 (Device selection)
H'11 (Clock mode selection)
H'3F (New baud rate setting)
H'27 (Programming unit inquiry)
H'4F (Status request)
H'4D (User area blank check)