Renesas FP-144L Informacje Techniczne

Przeglądaj online lub pobierz Informacje Techniczne dla Nie Renesas FP-144L. Renesas FP-144L Technical information [en] Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 34
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
To our customers,
Old Company Name in Catalogs and Other Documents
On April 1
st
, 2010, NEC Electronics Corporation merged with Renesas Technology
Corporation, and Renesas
Electronics Corporation took over all the business of both
companies.
Therefore, although the old company name remains in this document, it is a valid
Renesas Electronics document. We appreciate your understanding.
Renesas Electronics website: http://www.renesas.com
April 1
st
, 2010
Renesas Electronics Corporation
Issued by: Renesas Electronics Corporation (http://www.renesas.com)
Send any inquiries to http://www.renesas.com/inquiry
.
Przeglądanie stron 0
1 2 3 4 5 6 ... 33 34

Podsumowanie treści

Strona 1 - To our customers

To our customers, Old Company Name in Catalogs and Other Documents On April 1st, 2010, NEC Electronics Corporation merged with Renesas Technology C

Strona 2

IV SAFETY PAGE READ FIRST • READ this user's manual before using this user system interface cable. • KEEP the user's manual handy for futur

Strona 3 - User’s Manual

V WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emul

Strona 4

i Preface The HS1544ECH61H is a user system interface cable that connects an H8SX/1544 group E6000H emulator (HS1544EPH60H; hereinafter referred to a

Strona 5

ii Contents Section 1 Configuration...1 Section 2 Connection Pr

Strona 6

1 Section 1 Configuration CAUTION Use an NQPACK144SD socket (manufactured by Tokyo Eletech Corporation) for the FP-144L package IC socket

Strona 7 - IMPORTANT INFORMATION

2 Table 1 lists the HS1544ECH61H components. Please make sure you have all of these components when unpacking. Table 1 HS1544ECH61H Components No.

Strona 8 - DISCLAIMER

3 Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station WARNING Observe the precautions listed below.

Strona 9

4 2. After making sure the direction of the cable body connector is correct, firmly insert the cable body connector into the emulator station socket

Strona 10 - SAFETY PAGE

5 2.2 Connecting User System Interface Cable to User System WARNING Always switch OFF the user system and the emulator product before the USE

Strona 11

6 IC socket(NQPACK144SD manufacturedby Tokyo Eletech Corporation)User systemGuide pins4 projections to applyepoxy resin adhesive to Bottom view of IC

Strona 12 - Preface

Notice 1. All information included in this document is current as of the date this document is issued. Such information, however, is subject to chang

Strona 13 - Contents

7 2.2.4 Fastening Cable Head CAUTION 1. Use the screwdriver provided for tightening screws. 2. The tightening torque must be 0.054 N•m or less

Strona 14 - CAUTION

8 Fasten the user system interface cable head to the IC socket for an FP-144L package on the user system with the four screws (M2 x 10 mm) provided.

Strona 15

9 2.2.5 Fastening Cable Body Connect the cable body to the cable head. Cable bodyCable headRemove jigPush the remove jigRemovingUser system Figure 5

Strona 16

10 2.3 Recommended Dimensions for User System Mount Pad Figure 6 shows the recommended dimensions for the mount pad (footprint) for the user system

Strona 17 - User system interface cable

11 2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 7. Unit: mmTole

Strona 18

12 2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable

Strona 19

13 Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use the screwdriver provided f

Strona 20

14 MCUPin 1IC socket(NQPACK144SDmanufactured byTokyo Eletech Corporation)User systemScrews (M2 x 6 mm)Socket cover Figure 9 Installing MCU to User

Strona 21

15 Section 4 Verifying Operation 1. Turn on the emulator according to the procedures described in the H8SX/1650 E6000H Emulator User's Manual

Strona 22 - 2.2.5 Fastening Cable Body

16 Section 5 Notice 1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the ca

Strona 23 - 23.00 ± 0.15

H8SX/1544 FP-144LUser System Interface CableHS1544ECH61H User’s ManualUser’s Manual Rev.1.00 2006.06Renesas Microcomputer Development Environment Sy

Strona 24 - Tolerance: ±0.5 mm

17 6. Level-shift circuits with AVcc0, AVcc1, and Vref are mounted on the user system interface cable, as shown in figure 13. At shipment, the jump

Strona 25 - 13.3 21.5

18 AVcc0AVssAVcc1AVss1.03 k2 k1.03 k2 k+-+-5 V5 V13P4AVcc of MCU of the emulator stationSettings of short connector:Between pins 1 and 2: AVcc0Betwee

Strona 26

H8SX/1544 FP-144LUser System Interface CableHS1544ECH61H User's ManualPublication Date: Rev.1.00, June 28, 20

Strona 27

Sales Strategic Planning Div. Nippon Bldg., 2-6-2, Ohte-machi, Chiyoda-ku, Tokyo 100-0004, Japanhttp://www.renesas.comRefer to

Strona 28

1753, Shimonumabe, Nakahara-ku, Kawasaki-shi, Kanagawa 211-8668 JapanH8SX/1544 FP-144LUser System Interface CableREJ10J1393-0100HS1544ECH61H User’s M

Strona 30

1. These materials are intended as a reference to assist our customers in the selection of the Renesas Technology Corp. product best suited to the cu

Strona 32 - User System Interface Cable

I IMPORTANT INFORMATION READ FIRST • READ this user's manual before using this user system interface cable. • KEEP the user's manual handy

Strona 33 - RENESAS SALES OFFICES

II LIMITED WARRANTY Renesas warrants its user system interface cables to be manufactured in accordance with published specifications and free

Strona 34 - HS1544ECH61H User’s Manual

III State Law: Some states do not allow the exclusion or limitation of implied warranties or liability for incidental or consequential damages, so

Komentarze do niniejszej Instrukcji

Brak uwag