Event
Acquires trace information, controlling the start and end of trace acquisition with the specified condition.
Figure 5.74 Range Trace Setting (Event)
[Start Event]: Selects the event point for which the condition to start trace acquisition has been set.
[Stop Event]: Selects the event point for which the condition to stop trace acquisition has been set.
[Edit…]: Changes the setting for the selected event point.
[Cyclic]: When this box is checked, the event sequencing is configured so that the events reset
themselves which causes tracing to be restarted when the start event occurs after the stop event.
Starts and stops trace acquisition when the conditions for starting and ending are satisfied, respectively. Selecting
[Cyclic] allows a continuous acquisition of trace information that can be acquired with the specified condition.