5.2 Problems During Operation
This section describes the troubleshooting for problems that may occur during operation.
(1) One of the following errors is displayed on the output panel.
Error (E1000001) : E1/E20/MINICUBE2/COMx communication time out.
Error (E1000009) : E1/E20/MINICUBE2/COMx
Cause 1:
The USB cable might not be connected properly or the USB driver might not have been installed
normally.
Action 1:
See 5.1 Problems During Startup and take an appropriate action.
Cause 2:
The installed USB driver is not displayed in the Device Manager.
Alternatively, the “!” or “×” is prefixed.
Action 2:
<1> With RFP connected to the host machine, right-click the driver marked with the “!” or “×”, and then
click [Uninstall].
<2> Execute [Scan for hardware changes] in the Device Manager.
<3> Reinstall the USB driver by Plug and Play.
Cause 3:
The tool might not have been recognized (when connected via a USB hub).
Action 3:
Try the following:
<1> Disconnect the USB cable and then reconnect it.
<2> Connect the USB connector to another port on the USB hub.
<3> If the above measures do not resolve the problem, do not use the USB hub but directly connect the
USB connector to the USB port of the host machine main unit.
(2) The following message is displayed in the output panel and the flash memory programming
mode cannot be entered.
Error (E1002001): No response from Target Microcontroller (FLMD).
Error (E1002002): No response from Target Microcontroller (RESET).
Error (E1002003): No response from Target Microcontroller (FREQ).
Cause 1:
The wrong microcontroller name might be selected in the [Create a new workspace] dialog box.
Action 1:
Select the same name as that of the target microcontroller.
Cause 2:
No clock might be able to be supplied to the target microcontroller.
Action 2: