Renesas SuperH SH7280 Series Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Networking Renesas SuperH SH7280 Series. S550-SFWv3 User`s Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - S550-SFWv3

Serial Flash Programmer Operation Manual S550-SFWv3 Sunny Giken Inc.

Strona 2 - Serial Flash Programmer

● Top Side View Connector Function SERIAL Cable connector for connecting the target. ● Bottom Side View Connector Function US

Strona 3 - Table of Contents

④ Complete Downloading ・ When the dialog “DownLoad Complete” appears, downloading is complete. ・ In “Multi Data Mode”, the data with the smallest

Strona 4

8.1.3. Programming ① Download ・ Download programming data to S550-SFWv3. *The programming data shall be downloaded to the main unit for stand-alo

Strona 5 - 1. Outline

8.2. Stand-alone Initialization You can initialize data that is stored in the S550-SFWv3 internal memory on unit basis for security purposes. The

Strona 6 - 1.2. System Configuration

8.3. Center Display Modes 8.3.1. Mode Transition Diagram Following illustrates mode transitions of S550-SFWv3 center display. (Single

Strona 7 - 2. Specifications

(Multi Data Mode) FUNCFUNCSTART STARTSTARTSTARTSTARTSTART "P.3"."P.4&quo

Strona 8 - 2.4. Programmable Device

8.3.2. Normal Display Mode This is the screen when power is turned on. The S550-SFWv3 displays the checksum lower 1 byte of the data stored in

Strona 9

8.3.4. Programming Information Display The S550-SFWv3 displays the programming information of the data stored in the internal memory of the main

Strona 10

8.3.6. Data Switch Display With the “Multi Data Mode”, you can select programming data on S550-SFWv3. Following shows how to select the data. *Whe

Strona 11

9. Messages and Warnings 9.1. Message Dialogs Display Contents S550-SFWv3 already started. Displayed when trying to start up the control soft

Strona 12

Display Contents Some Maintenance setting items has been edited. Do you want to replace the existing items? Confirmation whether to valida

Strona 13

2.6. Connector Pins Specifications ・ Connector Pins (S550-SFWv3 Main unit) ・ Model : XG4C-1434 OMRON Corporation ・ Pin Assignment (S550-

Strona 14 - 4. Connections

Display Contents Initialize... Displayed while initializing. Finish Displayed when programming has been complete. Initialize Stop... Displayed w

Strona 15

9.2. LED Status List Operation Condition LED Status No settings made by PC After “POWER” is lighted, “PASS”, “ID ERR”, and “FAIL” will blink o

Strona 16

Operation Condition LED Status Firmware updating “PASS”,“ID ERR” and “FAIL” will all be lighted. Firmware updating complete “PASS”, “ID ERR” and

Strona 17

9.4. List of Error Information on Center Display Center display status Descriptions "0","0" Programming is canceled after S

Strona 18

9.6. Initialized Settings (factory setting) List Items Default status (Factory setting) Programming data Data set in the device setting screen

Strona 19

10. Troubleshooting 10.1. Mode entry error occurs when programming The mode entry error occurs while preparing for programming. Following shows

Strona 20 - 5. Setting Up

10.6. Memory error occurs when programming Memory error occurs when the S550-SFWv3 main unit ROM is damaged. Following shows how to resolve. ① D

Strona 21

Version Revised contents Revised date Rev.A First edition 2010/03/29 Rev.B Changes of the whole ・The description has been changed from the “R

Strona 22

Rev.C 2.3. System Requirements ・Windows 7(32bit) has been added to OS. 5.1. Installing USB driver ・"5.1.1 Windows 7(32bit)" has been added

Strona 23

Rev.G 2.2.Function Specifications ・The Operation Mode has been changed. 2.7. Target Connecting Cable ・The explanation of Target Connecting Cable has

Strona 24

2.7. Target Connecting Cable 2.7.1. 14 – 14 Standard Cable The attached connecting cable is a straight cable. In case the connector specificat

Strona 25

Overseas Standard ・CE Mark Obtained (EMI:EN55011 Group1 ClassA ,EMS:EN61000-6-2) ・FCC Compliance This device complies with part 15 of the FCC Rul

Strona 26

2.7.4. 14 – 14 Custom2 Cable(model: S550-SFW-CB2) The optional connecting cable converts 14pin connector to 14pin(Applicable for RX Family(except

Strona 27

3. Circuitry Examples Refer to the file “S550-SFWv3 Examples of circuit for serial programming”in the enclosed CD-ROM. 4. Connections S550-SFW

Strona 28

4.2. Connection for Stand-alone Programming / Stand-alone Initializing The connection when you program from the lone S550-SFWv3 to the target (st

Strona 29

4.3. Connection for Remote Programming The connection when you program remotely to the target from the PC using the control software though S550-

Strona 30

 (When supplying voltage to the target board from S550-SFWv3 – Single CH Mode) Target connection cable Your tar

Strona 31

 (When supplying voltage to the target board using an external power supply - Multi CH Mode) S550-SFWv3 USB cable SFWv3 controlsoftware PC (OS:

Strona 32

 (When supplying voltage to the target board from S550-SFWv3 - Multi CH Mode) USB cable SFWv3 controlsoftware

Strona 33 - 6. Control Software

Serial Flash Programmer S550-SFWv3 The contents of this manual may be revised without notice. We, Sunny Giken Inc. shall not be responsible for

Strona 34

5. Setting Up 5.1. Installing USB driver When S550-SFWv3 is connected to a PC by USB, Windows automatically detects a new hardware and creates

Strona 35

iii) The following Dialog will be displayed. Press "Finish" button. Serial Flash Programmer[S550-SFWv3] Operat

Strona 36

5.1.2. Windows 7(64bit) i) Execute "dpinst.exe" of the “Driver64” folder. "Device Driver Installation Wizard" Dialog will be

Strona 37

iii) The USB driver package is being installed. Please wait for a moment. iv) The following Dialog will be displayed. Pre

Strona 38

5.1.3. Windows Vista i) “Found New Hardware” dialog will be displayed. Select “Locate and install driver software”. ii) Sele

Strona 39

iii) The driver files will be automatically copied and installation will be completed. Serial Flash Programmer[S550-SFWv3

Strona 40

5.1.4. Windows XP i) “Found New Hardware Wizard” dialog will be displayed. Select “Install from a list or specific location” and press [Next].

Strona 41

iii) The driver files will be automatically copied and installation will be completed. Serial Flash Programmer[S550-SFWv3] Operation Manual 26

Strona 42 - 6.2. Device Setting Screen

5.1.5. Windows 2000 i) ”Found New Hardware Wizard” dialog will be displayed. Press [Next]. ii) Select ”Search for a suita

Strona 43

iii) Select “Specify a location” and press [Next]. iv) Specify “USBDrv” folder in the attached CD-ROM for the area to copy fil

Strona 44

Table of Contents 1. Outline...

Strona 45

vi) The driver files will be automatically copied and installation will be completed. Serial Flash Programmer[S550-SFWv3] Operation

Strona 46

5.2. Installing Control Software Using the attached CD-ROM, execute “Setup.exe” in “Software” folder. The following is the software installatio

Strona 47

iii) Files are automatically copied and installation will be completed. 5.3. Uninstalling Control Software From the Con

Strona 48

6. Control Software 6.1. Main Screen 6.1.1. Main Screen (Single Data Mode, or Single CH Mode) (Multi Data Mode)

Strona 49

(Multi CH Mode) For “Multi CH Mode”, see “6.3.1 Maintenance Initial Setting Screen”. Serial Flash Programmer[S550-SFWv3] O

Strona 50

<Information section> Items Descriptions Shows MCU manufacture. Shows MCU series. Shows MCU model. * The device displayed (ECC) after the

Strona 51

<Project menu> Items Descriptions “New”: Discards the current settings and starts new setting. “Open...”: Opens a project file. “Save As

Strona 52

6.1.2. About Screen (Single CH Mode) (Multi CH Mode) Items Descriptions Shows the control software version. Sh

Strona 53

6.1.3. Initialize Setting Screen The following screen is displayed only in the "Multi CH Mode". <<S550-

Strona 54

6.1.4. UpLoad Setting Screen The following screen is displayed only in the "Multi CH Mode". <<S550-SFWv3

Strona 55

7.1.1.1. Process Flow up to Programming... 59 7.1.1.2.

Strona 56

6.1.5. DownLoad Setting Screen The following screen is displayed only in the "Multi CH Mode". <<S550-SF

Strona 57 - 6.4. Execution Screen

6.1.6. Program Setting Screen The following screen is displayed only in the "Multi CH Mode". <<S550-SFW

Strona 58

6.2. Device Setting Screen 6.2.1. Device Setting Screen <<Device section>> Items Descriptions Select MC

Strona 59

Items Descriptions Opens the clock frequency setting screen. (See “6.2.3 Clock Frequency Setting Screen”.) Shows main clock frequency. Shows per

Strona 60 - 7. Remote Mode

<<Main menu>> Items Descriptions “Main”: Moves to Main screen. *After a confirmation message, setting contents will be discarded.

Strona 61

6.2.2. Device Detail Display Screen Items Descriptions Shows MCU model. Shows the minimum value of the ROM block addr

Strona 62

6.2.4. User Program File Load Screen Select a user program file to load and press “Open”. When the file is loaded successfully,

Strona 63

6.2.5. User Program Edit Screen Items Descriptions Shows MCU model. Shows the user’s program name with the path

Strona 64

Items Descriptions Searches user’s program data or address. (See “6.2.6 User’s Program Data Search Screen”.) Fills the selected area with the id

Strona 65

6.2.8. User’s Program Data Saving Screen Items Descriptions Selects all area for saving. Selects address range for savi

Strona 66

1. Outline 1.1. Precautions Thank you for purchasing our product. Please read this operation manual carefully to understand the functions of t

Strona 67

6.2.10. ROM Area Block Information Setting Screen Items Descriptions Selects “Keep Device Lock Bits” for lock bit process

Strona 68

6.2.11. ROM Protection Setting Screen (R32C/100 Series) Items Descriptions Sets whether to execute BP Bit_Program for all BP0 and BP1

Strona 69

(78K,RL78 Family) Items Description Sets whether to execute Flash Option. Execution of the chip erase command is disabled. Execution of the

Strona 70

6.2.12. Input Vcc Setting Screen Items Descriptions Input vcc. Reflects the setting content and closes the screen. Discards the setting co

Strona 71

<Initial Setting section> Items Descriptions Enables saving the action log (operation execution log). Set saving destination for the ac

Strona 72

6.3.2. Password Setting Screen Items Descriptions Sets a password. Maximum of 8 single byte characters can be set. *The password is ref

Strona 73

6.3.3. Execution Operation Log Display Screen <Logging section> Items Descriptions Select a log file to displa

Strona 74

6.4. Execution Screen 6.4.1. Execution Screen (Single CH Mode) Serial Flash Programmer[S550-SFWv3] Operation Manual

Strona 75

(Multi CH Mode) <<Information section>> Items Descriptions Shows MCU manufacturer. Shows MCU series

Strona 76

<<Pass/Fail Counter section>> Items Descriptions Shows the number of successful programming. Shows the number of programming errors

Strona 77

1.2. System Configuration The entire system configuration of the Serial Flash Programmer S550-SFWv3 is illustrated below.

Strona 78

7. Remote Mode 7.1. Single CH Mode 7.1.1. Remote Programming 7.1.1.1. Process Flow up to Programming The following section describes the ope

Strona 79

7.1.1.2. Maintenance Settings With the control software, you can change S550-SFWv3 main unit setting. The following illustrates an example of th

Strona 80

② Save execution operation log ・ Check the “Ena” check box to save execution operation log. ・ To select the saving destination for execution op

Strona 81

③ Save device setting file ・ To select the saving destination for the device setting file, click the “Save Directory” button and select the des

Strona 82

④ Set password ・ Check the “Enable” check box to set a password to S550-SFWv3 main unit. Uploading data to program will require the password when

Strona 83

⑤ Select extended operation mode ・ Check the “Enable Expansion Action Mode” check box to select the extended operation mode. Standard operation m

Strona 84

⑥ Select power saving mode ・ Check the “Enable Power Save Mode” check box to set power saving mode of the S550-SFWv3 main unit. *When power sa

Strona 85

⑦ Select mute ・ Check the “Mute” check box to mute S550-SFWv3 main unit’s buzzer sound. Serial Flash Programmer[S550-SFWv

Strona 86 - Programming

⑧ Select “Multi Data Mode” ・ Check the “Enable Multi Data Mode” check box to set the “Multi Data Mode”. ・ Maximum of 4 data can be set or do

Strona 87

⑨ Select “Multi CH Mode” ・ Check the “Enable Multi CH Mode” check box to set the "Multi CH Mode". Please see "7.2.1.2 Maintenanc

Strona 88

2. Specifications 2.1. Specifications Operating Environment Ambient temperature : 0°C to 40°C Humidity: below 80% (non-condensing) Storage E

Strona 89

7.1.1.3. Data Settings With the control software, you can set the data to program. The following illustrates an example of the programming data

Strona 90

③ Select a device ・ Select the target device from “Maker” list, “MCU” list and “Type” list. ④ Select communication m

Strona 91

⑤ Select clock frequency ・ Click “Set Freq” button, input the clock frequency of the target board and select the clock multiplying rate from th

Strona 92

⑦ Edit data ・ Data is editable by clicking the “Edit” button, “Set ID” button, “Set Block” button” and/or “Set Protect” button. *For Editing, see

Strona 93

⑨ Confirm data ・ Confirm whether programming data is correct. ・ After checking, click the “Set” button and move to the main screen.

Strona 94

⑩ Save project (device setting) file (Single Data Mode) ・ You can save the contents set in the device setting screen and maintenance screen as a

Strona 95

⑪ Load a project file ・ Load the project file (device setting information and maintenance screen information) saved with the operation10 descri

Strona 96

⑫ Discard device setting (Single Data Mode) ・ You can discard the contents set in the device setting screen. ・ Select “New” from the “Project” m

Strona 97 - 8. Stand-alone Mode

⑬ Copy device setting (Only in the “Multi Data Mode”) ・ Select data of the copy origin and click the “Copy” button and move to the “Copy Informat

Strona 98

③ Start downloading ・ Click the “DownLoad” button. ・ The progress bar will show the downloading progress status. ・ Click “Cancel” to cancel

Strona 99

2.4. Programmable Device The Renesas built-in Flash Memory Microcomputers are the programmable devices. Some devices are under evaluation or no

Strona 100

④ Downloading complete ・ Downloading is complete when the execution screen appears. ⑤ Start programming ・ Click t

Strona 101 - Downloading”.)

⑥ Programming complete ・ When the “Result” area is yellow-green, programming is complete. When the area is in red, error occurred in programming.

Strona 102

7.1.2. Uploading You can upload the programming data stored in S550-SFWv3 to the control software (Upload). The following procedures show how to u

Strona 103 - 8.3. Center Display Modes

④ Start Uploading ・ The progress bar will show the uploading progress status. ・ Click “Cancel” to cancel uploading in midstream. *If

Strona 104

(Multi Data Mode) e.g.) Uploading 4th data stored in S550-SFWv3 to the 3rd data (i) Select uploading destination data number (1 through 4). Cl

Strona 105

7.1.3. Initialization You can initialize data that is stored in the S550-SFWv3 internal memory on unit basis for security purposes. The followings

Strona 106

7.2. Multi CH Mode 7.2.1. Remote Programming 7.2.1.1. Process Flow up to Programming The following section describes the operations from setti

Strona 107

7.2.1.2. Maintenance Settings With the control software, you can change S550-SFWv3 main unit setting. The following illustrates an example of th

Strona 108 - 9. Messages and Warnings

② Select Multi CH Mode ・ Check the “Enable Multi CH Mode” check box to set the "Multi CH Mode". ・ It is possible to Initialize/Upload

Strona 109

③ Start downloading ・ Click the “Program” button. ・ Select channels and click "OK" button. * In the "DownLoad" list, the it

Strona 110

2.5. S550-SFWv3 External Appearance The external appearance of S550-SFWv3 is shown below with descriptions of switches, LEDs, connectors and acc

Strona 111 - 9.2. LED Status List

*If the data in the S550-SFWv3 main unit and the data in the control software are identical, downloading will not be processed with the message “It

Strona 112 - 9.3. Buzzer Sound List

④ Downloading complete ・ Downloading is complete when the execution screen appears. ⑤ Start programming ・ Click t

Strona 113

⑥ Programming complete ・ When the “Result” area is yellow-green, programming is complete. When the area is in red, error occurred in programming.

Strona 114 - *With buzzer sound

7.2.2. Uploading You can upload the programming data stored in S550-SFWv3 to the control software (Upload). The following procedures show how to u

Strona 115 - 10. Troubleshooting

④ Start Uploading ・ The progress bar will show the uploading progress status. ・ Click “Cancel” to cancel uploading in midstream. *If

Strona 116

7.2.3. Initialization You can initialize data that is stored in the S550-SFWv3 internal memory on unit basis for security purposes. The followings

Strona 117

④ Start Initializing ・ Click the “Initialize” button and the confirmation dialog asking, “Do you want to initialize?” Click the “OK” button to sta

Strona 118

8. Stand-alone Mode 8.1. Stand-alone Programming 8.1.1. Process Flow up to Programming The following section describes the operations from se

Strona 119

8.1.2. Downloading You can store the data set with the control software in the S550-SFWv3 main unit (Download). The following procedure shows how

Strona 120 - ・FCC Compliance

③ Start Downloading ・ Click the “DownLoad” button. ・ The progress bar will show the downloading progress status. ・ Click “Cancel” to cancel

Komentarze do niniejszej Instrukcji