Renesas H8SX/1520 Informacje Techniczne

Przeglądaj online lub pobierz Informacje Techniczne dla Nie Renesas H8SX/1520. Renesas H8SX/1520 Technical information Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 25
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
To our customers,
Old Company Name in Catalogs and Other Documents
On April 1
st
, 2010, NEC Electronics Corporation merged with Renesas Technology
Corporation, and Renesas
Electronics Corporation took over all the business of both
companies.
Therefore, although the old company name remains in this document, it is a valid
Renesas Electronics document. We appreciate your understanding.
Renesas Electronics website: http://www.renesas.com
April 1
st
, 2010
Renesas Electronics Corporation
Issued by: Renesas Electronics Corporation (http://www.renesas.com)
Send any inquiries to http://www.renesas.com/inquiry
.
Przeglądanie stron 0
1 2 3 4 5 6 ... 24 25

Podsumowanie treści

Strona 1 - To our customers

To our customers, Old Company Name in Catalogs and Other Documents On April 1st, 2010, NEC Electronics Corporation merged with Renesas Technology C

Strona 2

4 2. After making sure the direction of the cable body connector is correct, firmly insert the cable body connector into the emulator station socket

Strona 3 - User’s Manual

5 2.2 Connecting User System Interface Cable to User System WARNING Always switch OFF the user system and the emulator product before the USE

Strona 4

6 2.2.3 Inserting Cable Head CAUTION Check the location of pin 1 before inserting. Align pin 1 on the IC socket for an FP-100M package on the u

Strona 5 - Preface

7 Fasten the user system interface cable head to the IC socket for an FP-100M package on the user system with the four screws (M2.6 x 12 mm; with fou

Strona 6 - Contents

8 2.2.5 Fastening Cable Body Connect the cable body to the cable head. Cable bodyCable headRemove jigPush the remove jigsUser systemRemoving Figure

Strona 7

9 2.3 Recommended Dimensions for User System Mount Pad Figure 5 shows the recommended dimensions for the mount pad (footprint) for the user system w

Strona 8

10 2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6. 63.5066.0417

Strona 9

11 2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable

Strona 10 - User system interface cable

12 Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use a Philips-type screwdriver

Strona 11

13 MCUPin 1IC socket (IC149-100-054-B51manufactured by YAMAICHI ELECTRONICS Co., Ltd.)User systemScrews (M2.6 x 6 mm) with flat washersSocket cover F

Strona 12 - CAUTION

Notice 1. All information included in this document is current as of the date this document is issued. Such information, however, is subject to chang

Strona 13

14 Section 4 Verifying Operation 1. Turn on the emulator according to the procedures described in the H8SX/1650 E6000H Emulator User's Manual

Strona 14 - 2.2.5 Fastening Cable Body

15 Section 5 Notice 1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the ca

Strona 15 - 0.5 x 24 = 12.00 ± 0.05

16 6. A level-shift circuit with AVcc0 and AVcc1 is mounted on the user system interface cable, as shown in figure 12. At shipment, the jumper pin

Strona 16

Renesas Microcomputer Development Environment System User's Manual H8SX/1520 Group FP-100M User System Interfa

Strona 17 - 16.0 21.5

Sales Strategic Planning Div. Nippon Bldg., 2-6-2, Ohte-machi, Chiyoda-ku, Tokyo 100-0004, Japanhttp://www.renesas.comRef

Strona 18

1753, Shimonumabe, Nakahara-ku, Kawasaki-shi, Kanagawa 211-8668 JapanH8SX/1520 Group FP-100M User System Interface CableREJ10B0173-0100HS1527ECH61H U

Strona 19

H8SX/1520 Group FP-100MUser System Interface CableUser’s ManualUser’s Manual Rev.1.00 2005.01Renesas Microcomputer Development Environment SystemHS1

Strona 20

1. These materials are intended as a reference to assist our customers in the selection of the Renesas Technology Corp. product best suited to the c

Strona 21 - Section 5 Notice

i Preface The HS1527ECH61H is a user system interface cable that connects an H8SX/1520 group E6000H emulator (HS1527KEPH60H; hereinafter referred to

Strona 22

ii Contents Section 1 Configuration...1 Section 2 Connection Pr

Strona 23 - User's Manual

1 Section 1 Configuration CAUTION Use an IC149-100-054-B51 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the FP-100M package

Strona 24 - RENESAS SALES OFFICES

2 Table 1 lists the HS1527ECH61H components. Please make sure you have all of these components when unpacking. Table 1 HS1527ECH61H Components No.

Strona 25 - HS1527ECH61H User’s Manual

3 Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station WARNING Observe the precautions listed below.

Komentarze do niniejszej Instrukcji

Brak uwag